K4000 |
 |
Series Trace Gas Analyzer
|
 |
|
|
|
Based on patent pending peak slicing G.C. method that separates completely the Argon and the Oxygen!
Hydrocarbon system measurement without the use of a FID. Avoid all inconveniences of a Flame Ionization Detector :
- Self cleaning detector. No periodic cleaning like the FID;
- No Fuel and safety valve needed;
- No air and zero air generator requested.
|
Contrôle Analytique, a leading manufacturer of trace gas
analyzers since 1995, is now offering the K4000 analyzer
series with its patent pending plasma emission detector.
The most versatile gas chromatograph on the market, the
K4000ng redefines the gas measurement by integrating a
complete solution in a compact rackmount 4U. Configured to
your needs to measure a large number of impurities in different
backgrounds, the K4000ng uses not only plasma emission
detectors, but also many other kinds such as thermal conductivity
(T.C.D.), flame ionization (F.I.D.), and the new reduction
gas detector (R.G.D.). By implementing backflush, heart cut,
multiple sample loops, multiple separation columns and
multiple detectors, the K4000ng is the complete solution you
are looking for. With its capability to measure down to the
ppb level, the K4000ng becomes the only one analyzer that
your industry needs.
To extend its flexibility, a slave chassis can be added to the
K4000ng mainframe. Everything remains under control of the
mainframe to deliver a unified configuration that can replace
as much as 8 analyzers! Also, ask Contrôle Analytique's team
about the K4000ng portable cart, which is a solution that is
commonly used in the semiconductor industries. All of these
features, with an incredible simplicity of use and a fast startup
time!
Air separation, semi-conductors, steel industries, electronics,
specialty gas and laboratories are all fields of application
in which the K4000ng can become a strong tool. Typical measurements
are impurities found in H2, O2, N2, Ar, CH4, CO, CO2,
Ne, Xe, Kr, He and light hydrocarbons. Other applications are
possible under demand.
The system is designed to operate as a stand-alone process
gas analyzer in stand-alone mode. No other data handling
equipment or software is required to quantify peak data;
the concentration for each impurity is displayed directly
on the K4000ng's screen. To communicate results to external
devices, use the K4000ng's 4 to 20 mA outputs or the Contrôle
Analytique's report software connected to the Internet/
Ethernet port.
With its new user interface, the K4000ng is now fully controllable
over the Internet or a local network. Monitor and run
your analyzer from anywhere around the world as if you
were in front of it. Ask Contrôle Analytique technical support's
engineers to establish a connection with your analyzer
to assist you in troubleshooting your system and resolve
problems. With the K4000ng, everything you need to measure
gases is in the box!
The K4000ng is a basic mainframe that Contrôle Analytique
customizes for your application. The analytical section can be
configured to perform parallel analysis. Contrôle Analytique
builds the K4000ng with signal conditioning circuits, columns,
detectors, valves and ovens depending on the targeted purpose.
Going from the % to the ppb level, implementing single or
multiple backgrounds or meeting medical specifications, the
K4000ng is optimized for your analytical application. With an
improved software based on Windows XP Embedded, the
K4000ng becomes more and more flexible and user-friendly.
Change peak data, detectors, oven temperature, and more!
|
- Gas purifier: the GP-200 series gas purifier is used to generate high quality carrier gases and zero calibration gas.
- Temperature regulated electronically (intelligent version only)
- Diagnostic LED indicators (intelligent version only)
- RS-485 compatible (intelligent version only)
- Sample stream selection system: the K4000ng can be fed by a Manual Sampling System (MSS) or by
a High Purity Sampling System (HPS2). They both allow a remote or a local sample stream selection.
Exempt of sample stream cross contamination, air diffusion or dead volume, these sample stream selection
systems (U.S. Patent No 6.637.277) are simply the best on the market.
- Calibration devices: use the GCS-100 Gas Calibration System to start-up your system with the right calibration.
This intelligent capillary based orifice gas blending device lets you manage the dilution of a span gas with
a zero gas in order to reach a low level of impurity.
- Slave chassis: for complex configuration, auxiliary chassis can be added to extend the application that requires
more valves, columns, detectors or anything else. The K4000ng communicates with its slave chassis by serial port.
- Auxiliary ovens: different kinds of custom ovens can be added to the system in separate auxiliary chassis to provide
optimum temperature changes needed in certain applications (ex: temperature ramping).
- Proprietary column for the separation of Ar and O2: these columns are used for the measurement of Ar and O2.
The plasma detector for an Argon impurity has a sensitivity of 100 ppt.
- H2 permeation device: used to eliminate hydrogen from a sample when measuring impurities in pure hydrogen.
- Various traps: different kinds of traps can be mounted on the rear panel to clean a background gas in order to obtain
the zero baseline needed for a proper analysis of resolved impurity traces. The trap used is dependant upon the application.
Generally speaking, a trap is used in a configuration where the background part is vented. They are available for the H2 and
for the O2. Some of these traps can be regenerated directly in place.
|
- Easy configuration and stand-alone operation
- 8 isolated 4-20 mA outputs for peak values (software calibration)
- 1 isolated 4-20 mA output for a chromatogram signal (software calibrated)
- Remote range I.D. contacts (application dependent)
- 2 alarm dry contacts
- System status dry contact
- Electronic carrier and sample flow PID control system
- Internet cabinet temperature regulation eliminating temperature drift
(kept stable for ambient temperature ranging from 15 to 35ºC)
- Internet/Ethernet control software to control the K4000ng from anywhere around the world
|
- Report monitoring software: Contrôle Analytique can provide you with a software to monitor directly on a PC the chromatograms
and the process results computed by the K4000ng. This software uses an Internet/Ethernet link and can also be used to generate
statistics and historical values.
- Quick check configuration: when the background gas and the carrier gas are the same, a quick check allows a total gas purity verification
as a GO-NO-GO. One sample injection of all impurities is performed with the G.C. column bypassed. Based on the degree of change on the
baseline, the total gas impurity can be evaluated. Taking less than 30 seconds, it is a useful option for troubleshooting a distribution line
integrity in a semiconductor industry, for example. In some cases, a different gas than the carrier one can be used.
- Please consult factory.
- Remote starting digital input
- 2 isolated analog inputs for customer's needs
- 2 isolated digital inputs for customer's needs
- 1 dry contact for customer's needs
|
| Detectors Types |
- Plasma emission detector: patent pending detector usable with Argon, Helium or Neon carrier gas.
- Thermal conductivity detector (T.C.D.)
- Flame ionization detector (F.I.D.)
- New reduction gas detector (R.G.D.)
- New detectors to come!
|
| G.C. Valve |
|
| Gas Lines |
All stainless steel, passivated or electro-polished |
| Columns |
- Molecular sieve, porapak, Hayesep and various
other fillings of different catalyst materials; depends
on the application and on the interference caused
by various backgrounds
- Different types and sizes (application dependant)
|
| Operating Temperature |
- 40°C, electronically regulated inside the analyzer
- Ambient temperature required: between 15 and 35°C
|
| Power Consumption |
150 watts (application dependant) |
| Supply |
115 Vac, 50-60 Hz or 220 Vac, 50-60 Hz |
| Weight |
11 to 27 Kg (25 to 60 lbs) |
| Dimensions |
K4000ng chassis or slave chassis:
Standard rack-mount 4U enclosure:
- Width: 19" (482 mm)
- Height: 7" (177 mm)
- Depth: 24" (600 mm)
|
| Connectors |
- RJ-45 for Ethernet 10Base-T
- RJ-11 for RS-485 link to slave and auxiliary chassis
- USB for external mouse or keyboard
- 40 pins 5.08 pitch screw connector for I/Os
- Corcom 5EFM4S power entry module
|
| LDL |
The achievable LDL is ranging from 0.1 ppb to 20 ppb based on system configuration and specific impurities. |
| Drift/Repeatability |
Analytical system drift and repeatability will
range from ±1% to ±5% based on full scale,
system configuration and specific impurities. |
| Full Scale |
The maximum measuring range for most of impurities
is 100% full scale. The minimum measuring
range could be set as low as 50 ppb.
This is also based on system configuration and
specific impurities. |
| Gas Connections |
- 1/8" VCR for traps connections or sample, supporting gas and carrier inlets
- 1/8" compression Swagelok
|
| Sample Flow |
- Adjustable from 0 to 50 cc/min (application dependant)
- Electronically monitored and regulated
|
| Sample Pressure |
10 to 20 PSI (application dependant) |
| Carrier Flow |
- Adjustable from 10 to 175 cc/min
(application dependant)
- Electronically monitored and regulated
- Automatic purging process
- Different carrier gas allowed inside the same system
(ex: Ar/He and N2)
|
| Carrier Pressure |
100 PSIG recommended (689.5 kPa). |
| Electronic System |
- Display: high resolution TFT color L.C.D. with C.C.F.L. backlight
- Multi processor system
- A/D converter: true 24 bit resolution
- D/A converter: at least true 16 bit resolution
- Flow transducers and pressure sensors: thermal conductivity (flow tables are pre-loaded in the software)
- 4-20 mA isolated output:
- 600 ohms at 20 mA dc
- Fuse protection
- Transient protected
- Isolated from power ground and analyzer's electrical circuit
- Programmable for over- and under-drive in case of a system alarm
- Manual software control for calibration, monitoring and troubleshooting
- Digital outputs:
- Dry contact single polesingle throw (SPST)
- Snubber protection
- Fuse protection (1A 250VAC resistive load)
- Digital inputs:
- 24 VDC or VAC
- Transients and over voltage protected
- Fuse protection
- Isolated input
- Analog inputs:
- 0 to 5V
- 24 bit resolution
|
Also possible: BTEX, NO2, mercaptan and some sulfur compounds. Please concact factory.
|
| |
High (mm) |
Deep (mm) |
Wide (mm) |
| Standard rack mount 4U |
7" (177) |
24" (600) |
19" (482.6) |
|
|